Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| Type: | Lithium-Ion Battery Pack |
| Connection Mode: | Series and Parallel |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency

| Contents | Min. | Type | Max. | Tolerance | Unit |
| Absolute Maximum Rating | |||||
| Input Charging Voltage | 36.5 | V | |||
| Input Charging Current | 5 | 10 | A | ||
| Output Discharging Voltage | 20 | 32 | 36.5 | V | |
| Continuous Output Discharging Current | 5 | 10 | A | ||
| Ambient Condition | |||||
| Operating Temperature | -20 | 85 | ºC | ||
| Humidity (No Water-Drop) () | 0% | 80% | RH | ||
| PCBA Storage Condition PCBA | |||||
| PCBA Storage Temperature PCBA | -20 | 60 | ºC | ||
| Humidity (No Water-Drop) () | 0% | 60% | RH | ||
| Protection Parameters (for Single Cell). () | |||||
| Over-Charge Voltage Protection (OVP) | 3750 | ±30 | mV | ||
| Over-Charge Voltage Protection Release (OVPR) | 3500 | ±50 | mV | ||
| Over-Charge Voltage Protection delay | 1000 | ±500 | mS | ||
| Over-Discharge Voltage Protection (UVP) | 2000 | ±50 | mV | ||
| Over-Discharge Voltage Protection Release (UVPR) | 2500 | ±100 | mV | ||
| Over-discharge Voltage Protection delay | 1000 | ±1000 | mS | ||
| Over-Current Charge Protection (OCCP) | 20.0 | ±5.0 | A | ||
| Over-Current Charge Protection Delay | 1.0 | ±0.5 | S | ||
| Over-Current Charge Protection Release Delay Time | 2 | ±1.0 | S | ||
| Shutdown Voltage | 1800 | ±100 | mV | ||
| Shutdown mode delay | 3000 | ±500 | mS | ||
| Over-Current Discharge Protection 1(OCDP) | 20 | ±10 | A | ||
| Over-Current Discharge Protection 2(OCDP) | 40 | ±15 | A | ||
| Over-Current Protection Delay Time 1 (OCPDT) | 5 | ±0.5 | s | ||
| Over-Current Protection Delay Time 2 (OCPDT) | 80 | ±10 | ms | ||
| Short circuit Protection (SCP) | 300 | ±20 | A | ||
| Short circuit Protection Delay Time (SCPDT) | 400 | ±200 | uS | ||
| Short circuit protection Release | |||||
| Balance ON voltage | 3450 | mV | |||
| Balance ON Voltage difference | 50 | mV | |||
| Balance Cut-off voltage | 10 | mV | |||
| Balance resistance | 100 | R | |||
| Battery Charge Over Temperature Protection (T1,T2) | 50 | ±5 | ºC | ||